User's Manual

72 SMART-MR10 User Manual Rev 0B
Appendix A Technical Specifications
A.2.3 SMART-MR10 Connector and Cable Requirements
Custom cables for installing your SMART-MR10 can be created using the following guidelines:
Wire size must be 0.5 mm-1.25 mm (20-16 AWG)
Batt + connection must be protected by (value TBD) fast blow fuse
Serial data signals (TxD, RxD, signal ground) must be run in shielded cable. Connect shields to
ground at SMART-MR10 end only
CAN signal conductors must be twisted (40 twists/m, 12 twists/ft)
Use only the recommended mating connectors listed below. Use only gold plated pins
WARNING!: Failure to observe the given cable construction guidelines in this section
will result in damage to the wiring (not covered by warranty).
The connector used in the SMART-MR10 is an “AMPSEAL” dust and water sealed type produced by
Tyco. The following part numbers pertain to the mating connector required to make connections to the
SMART-MR10. These numbers are provided for information only and are not available from NovAtel
as separate parts.
Table 9: SMART-MR10 Mating Connectors
Table 10 details the part numbers for recommended fuses. These numbers are provided for
information only and are not available from NovAtel as separate parts.
Table 10: Recommended Fuses
Product Part Description Company Part Number
SMART-MR10 mating
connector (see Figure 27,
SMART-MR10 Evaluation
Cable on Page 68 and Figure
28, SMART-MR10
Streamlined Cable on Page
70)
23-pin sealed
receptacle
housing black
Tyco/
AMP
1-770680-1
Gold plated pins for SMART-
MR10 connector/loose
Pins, loose piece Tyco/
AMP
770854-3
Gold plated pins for SMART-
MR10 connector/strip
Pins, strip (reel) Tyco/
AMP
770520-3
Fuse Recommended Fuse/Fuse Holder
Blade Fuse 58V 5A Littelfuse 142.6185.450
Mini Blade Fuse 58V 5A Littelfuse 0997005