User's Manual

Commands Appendix B
SMART-MR10 User Manual Rev 0B 81
Field
Field
Name
ASCII
Value
Description
Field
Type
1LOG
(ASCII)
header
- This field contains the command name or
the message header depending on whether
the command is abbreviated ASCII or
ASCII respectively.
-
2 port See Table 16,
Detailed Serial Port
Identifiers on Page 82
Output port
(default = THISPORT)
Enum
3 message Any valid message
name, with an optional
A or B suffix.
Message name of log to output Char [ ]
4 trigger ONNEW Output when the message is updated (not
necessarily changed)
Enum
ONCHANGED Output when the message is changed
ONTIME Output on a time interval
ONNEXT Output only the next message
ONCE Output only the current message. (default)
ONMARK Output when a pulse is detected on the
mark 1 input, MKI
5 period Any positive double
value larger than the
receiver’s minimum
raw measurement
period
Log period (for ONTIME trigger) in seconds
(default = 0)
Double
6 offset Any positive double
value smaller than the
period.
Offset for period (ONTIME trigger) in
seconds. If you wished to log data at 1
second after every minute you would set
the period to 60 and the offset to 1 (default
= 0)
Double
7 hold NOHOLD Allow log to be removed by the UNLOGALL
command (default)
Enum
HOLD Prevent log from being removed by the
UNLOGALL command