User's Manual
Table Of Contents
- Introduction
- Installation and Setup
- Operation
- PC Utilities
- Bluetooth® Configuration
- Technical Specifications
- Commands
- B.1 Syntax Conventions
- B.2 BTCONTROL Enable/Disable Bluetooth
- B.3 COM Configure COM Port
- B.4 FRESET Clear Selected Data from NVM and Reset
- B.5 LOG Request Logs from the Receiver
- B.6 PDPFILTER Enable, disable or reset the PDP filter
- B.7 PDPMODE Select the PDP mode and dynamics
- B.8 RADARCFG Configure the ER output
- B.9 RESET Performs a hardware reset
- B.10 SBASCONTROL Set SBAS test mode and PRN
- Logs
- Replacement Parts
94 SMART-MR10 User Manual Rev 0B
Appendix C Logs
Field # Field type Data Description Format
Binary
Bytes
Binary
Offset
1 RADAR-
SIGNAL
header
Log header H 0
2 sol status Solution status, see Table 20, Solution Status on
Page 96
Enum 4 H
3 vel type Velocity type, see Table 19, Position or Velocity
Type on Page 95
Enum 4 H+4
4 speed Speed over ground (m/s) Double 8 H+8
4 varf freq External VARF output frequency (Hz) Double 8 H+16
5 radar freq Radar signal frequency (Hz) as output by the
Emulated Radar Out signal. See SMART-MR10
Evaluation Cable starting on Page 68.
Double 8 H+24
6 xxxx 32-bit CRC (ASCII and Binary only) Hex 4 H+32
7 [CR][LF] Sentence terminator (ASCII only) - - -