Manual 99a38 July 17, 2001
eDirectory Janitor Interval =
number_in_minutes
Specify the interval in minutes at which the janitor process is
executed. The janitor process is executed as soon as you change
this value and then recurs at the specified interval.
Supported values: 1 to 10080 minutes
Default: 60
The janitor process cleans up unused records, reclaims disk
space, and purges objects flagged for deletion.
eDirectory Backlink Interval =
number_in_minutes
Specify the interval in minutes at which backlink consistency
checking is performed. Backlink consistency checking is
executed as soon as you change this value. It then recurs at the
specified interval.
Supported values: 2 to 10080 minutes
Default: 780
A backlink indicates that an object in a replica has an ID on a
server where the replica doesn’t exist.
This process creates needed backlinks and deletes unnecessary
ones.
eDirectory Distributed Reference Link
Interval = number_in_minutes
Specify the interval in minutes at which distributed reference link
consistency checking is performed. Distributed reference link
consistency checking is executed as soon as you change this
value. It then recurs at the specified interval.
Supported values: 2 to 10080 minutes
Default: 780
A distributed reference link indicates that an object in a partition
has an ID in that partition where the actual object doesn’t exist.
This process creates needed distributed reference links and
deletes unnecessary ones.
eDirectory Trace File Length to Zero =
value
Delete the contents of the trace file. This parameter does not
delete the file itself. As soon as the file is cleared, the value of the
parameter resets to OFF.
Supported values: ON, OFF
Default: OFF
To use this parameter, you must also set the eDirectory trace to
file parameter to ON, because the trace file must be open for the
system to delete its contents.
Parameter Use to