User Guide

Utilities 275
Utilities Reference
103-000153-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
Parameter Use to
path Specify the path to UPS_AIO if you
moved it from the default directory.
DOWNTIME=number Specify the amount of time to run on
battery before system shutdown. If
power is restored before this time
elapses, no shutdown will occur. If a
low battery condition occurs before
this time elapses, an immediate
shutdown will occur.
Supported values: 30 seconds
minimum, no practical maximum limit.
Default: 300 seconds
MSGDELAY=number Specify the elapsed time before a
broadcast message is first sent to
users.
Supported values: 0 seconds
minimum, no practical maximum limit.
Default: 5 seconds
The broadcast message states the
time remaining until shutdown. This
message is generated automatically
by UPS_AIO.
MSGINTERVAL=number Specify the time interval between
broadcast messages sent to users.
Supported values: 20 seconds
minimum, no practical maximum limit
Default: 30 seconds
The broadcast message states the
time remaining until shutdown. This
message is generated automatically
by UPS_AIO.