The following messages include messages from the DSDIAG.NLM.
DSDiag-x-001: Process data not found. Exiting process.
Source: DSDIAG.NLM
Explanation: The report process could not locate its data to initialize the report.
Possible Cause: This is an unexpected error.
Action: Unload DSDIAGNOSTICS and then reload it. If the error persists, contact a
Novell
®
support provider.
DSDiag-x-002: Insufficient memory error.
Source: DSDIAG.NLM
Possible Cause: This server does not have enough memory to create a report.
Action: Exit all of the reports that are running except for the current report. Let the
current report run to completion and try again.
Action: Increase memory available to the server. See Freeing Server Memory
Temporarily in the Server Operating System Administration Guide.
DSDiag-x-003: Could not create initial context.
Source: DSDIAG.NLM
Explanation: An error occurred in the load process. This is an unexpected error.
Action: Check for possible configuration errors and reboot. If this error occurs
repeatedly, contact a Novell support provider.