User Guide
DSDIAGNOSTICS Messages 47
System Messages
103-000150-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
DSDiag-x-009: Error writing to log file, log file closed.
Source: DSDIAG.NLM
Explanation: The volume the log file is writing to is unmounted or the removable media (for
example, floppy, CD, or cartridge) is unavailable.
Action: Mount the volume or make sure the removable media is working properly.
DSDiag-x-010: Could not register with the Tool Manager.
Source: DSDIAG.NLM
Explanation: DSDIAGNOSTICS processes data and tracks resources used by each of the
reports and should always be available. This is an unexpected error.
Action: Exit the report, unload DSDIAGNOSTICS and then reload it.
DSDiag-x-011: Maximum NWSNUT portals reached.
Source: DSDIAG.NLM
Explanation: The maximum number of NWSNUT portals is set by the NUT NLM
TM
and is
version dependent. In this case, that maximum has been reached.
Action: Unload DSDIAGNOTICS reboot the server, and then reload
DSDIAGNOSTICS.
DSDiag-x-012: Unknown command line switch.
Source: DSDIAG.NLM
Explanation: An unknown command line switch was used.
Action: Use only supported switches. For a list of supported switches enter, /?.
DSDiag-x-013: USAGE: No switches.
Source: DSDIAG.NLM
Explanation: No switches are supported in this version of DSDIAGNOSTICS.
Action: Do not use command line switches in this version displayed in the message.