User Guide

78 System Messages
System Messages
103-000150-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
DSKSHARE-X-015: An internal error has occurred. The program could not allocate a
memory resource tag.
Source: DSKSHARE.DSK
Explanation: The program tried to allocate a memory resource tag, and the call failed.
Possible Cause: The server does not have enough memory available.
Action: Increase the memory available to the server. See Freeing Server Memory
Temporarily in the Server Operating System Administration Guide.
Possible Cause: An internal system error error has occurred.
Action: Load the driver again. If the problem persists, contact a Novell support
provider.
DSKSHARE-X-020: An internal error has occurred. The program could not allocate a
polling resource tag.
Source: DSKSHARE.DSK
Explanation: The program tried to allocate a polling resource tag, and the call failed.
Possible Cause: The server does not have enough memory available.
Action: Increase the memory available to the server. See Freeing Server Memory
Temporarily in the Server Operating System Administration Guide.
Possible Cause: An internal system error error has occurred.
Action: Load the driver again. If the problem persists, contact a Novell support
provider.
DSKSHARE-X-025: An internal error has occurred. The program could not get the
16:16 data selector.
Source: DSKSHARE.DSK
Explanation: The program could not set up a 16-bit data selector to the data group.
Action: Contact a Novell support provider.
DSKSHARE-X-030: This device driver is already loaded.
Source: DSKSHARE.DSK
Explanation: DSKSHARE can only be loaded once. Because DSKSHARE understands all
OS/2 disk drives, you do not need to load it more than once.
Action: No further action is required.