User Guide
98 System Messages
System Messages
103-000150-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
FILESYS-X-160: Internal compression error: file `name' volume number intermediate
size number. Length/Offset encode counts from intermediate file generation
(number) and intermediate file processing (number) mismatch invalidating
intermediate file.
Source: FILESYS.NLM
Possible Cause: This is an internal consistency check done by compression to guarantee the
integrity of the data being compressed. During file compression, an
intermediate file is created that describes the compressed version of the file.
The file contains codes describing what should be encoded in the compressed
version of the file. The codes in the intermediate file do not match those found
in the file being compressed. The file that was being compressed will remain
uncompressed, and the system will try again later to compress it.
Action: No immediate action is necessary. Note the volume number and watch for
more of these same alerts. Also, watch for other errors indicating that the
memory or disk is failing. If these alerts or other data corruption problems
happen often on a particular volume, the disk or hardware supporting the disk
should be repaired or replaced.
FILESYS-X-161: Internal compression error: file `name' volume number intermediate
size number. Large length/offset encode counts from intermediate file generation
(number) and intermediate file processing (number) mismatch invalidating
intermediate file.
Source: FILESYS.NLM
Possible Cause: This is an internal consistency check done by compression to guarantee the
integrity of the data being compressed. During file compression, an
intermediate file is created that describes the compressed version of the file.
The file contains codes describing what should be encoded in the compressed
version of the file. The codes in the intermediate file do not match those found
in the file being compressed. The file that was being compressed will remain
uncompressed, and the system will try again later to compress it.
Action: No immediate action is necessary. Note the volume number and watch for
more of these same alerts. Also, watch for other errors indicating that the
memory or disk is failing. If these alerts or other data corruption problems
happen often on a particular volume, the disk or hardware supporting the disk
should be repaired or replaced.