User Guide

SERVER Messages 581
System Messages
103-000150-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
SERVER-X-3806: Name: failed trying to rename SYS$LOG.ERR, file was deleted
instead.
Source: SERVER.EXE
Explanation: When the sys$log.err file reached it's maximum size, it should have been
renamed. The file was deleted instead, and a new sys$log.err file was created.
Possible Cause: Something prevented renaming the file. For example, the file may have been
open when the server tried to rename it.
Action: No action is necessary.
SERVER-X-3912: Invalid load file format.
Source: SERVER.EXE
Explanation: See message “SERVER-X-1134: Invalid load file format.” on page 550.
SERVER-X-3916: Error reading load file.
Source: SERVER.EXE
Severity: Warning
Explanation: See message “SERVER-X-1547: Error reading load file.” on page 559.
SERVER-X-4095: Unable to load the message/help support files.
Source: SERVER.EXE
Explanation: This informational message indicates that an error occurred when the
operating system tried to load the message and help files for an NLM it was
loading.
SERVER-X-4097: Unable to load module messages in preferred language # number;
the default language #number will be used.
Source: SERVER.EXE
Possible Cause: While loading an NLM, the operating system was not able to find the message
files for the preferred language. Instead, the operating system is using the
default language message files. Enter LANGUAGE LIST at the server
console prompt to see a list of languages and their numbers.