SPX-X-9: There is no LAN board registered with LSL.
Source: SPXS.NLM
Explanation: An attempt was made to load SPXS before loading a network board. The
operating system must have a board registered with the LSL with a valid IPX
and SPX frame type to initialize SPXS.
Action: Load a network board. Then load SPXS again.
SPX-X-10: The name device cannot be loaded by STREAMS.
Source: SPXS.NLM
Explanation: This message is probably preceded by error messages from the STREAMS
module.
Possible Cause: The user specified a duplicate or invalid device name.
Action: Make sure that the specified device name is valid, and is not a duplicate.
Possible Cause: The user is trying to load too many devices.
Action: Refer to any preceding error messages to help determine the exact cause of the
problem.
SPX-X-11: The name device cannot be loaded by STREAMS.
Source: SPXS.NLM
Explanation: This message is probably preceded by error messages from the STREAMS
module.
Possible Cause: The user specified a duplicate or invalid device name.
Action: Make sure that the specified device name is valid, and is not a duplicate.
Possible Cause: The user is trying to load too many devices.
Action: Refer to any preceding error messages to help determine the exact cause of the
problem.
SPX-X-12: Module_name STREAM module still in use. Unloading will have unknown
consequences.
Source: SPXS.NLM
Explanation: The indicated module is currently being referenced by another NLM program
or IntranetWare driver. Unloading the module while it is being used might
produce unwanted results.
Action: Wait until the module is not being used. Then try the unload again.