User Guide
Shared Messages for LAN Drivers 759
System Messages
103-000150-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
007: You need another MLID section heading in the NET.CFG file in order to load the
MLID again.
Source: TRXNET-DOS.LAN
Explanation: The driver cannot be loaded consecutively unless you edit the configuration
parameters and add a section heading for each instance in the NET.CFG file.
Action: Unload the TRXNET driver. Edit/create the NET.CFG file and add a Link
Driver section heading for each time the driver is to be loaded; then reload the
driver.
008: A NET.CFG is required to load the MLID again.
Source: TRXNET-DOS.LAN
Explanation: The driver cannot be loaded unless you create a NET.CFG file. A Link Driver
section heading must be edited into the NET.CFG file for each time the driver
is to be loaded.
Action: Unload the TRXNET driver. Edit and create the NET.CFG file and add a Link
Driver section heading for each time the driver is to be loaded.
009: The NET.CFG entry has been ignored.
Source: TRXNET-DOS.LAN
Explanation: The driver cannot be loaded consecutively unless you create a NET.CFG file
each time.
Action: Unload the TRXNET driver. Edit/create the NET.CFG file and add a Link
Driver section heading for each time the driver is to be loaded.
011: The MLID does not support frame type. The protocol keyword has been ignored.
Source: TRXNET-DOS.LAN
Explanation: An unsupported or incorrectly typed frame type has been specified with the
protocol keyword.
Action: Check the contents of the NET.CFG file, and verify the frame type assigned
under the PROTOCOL keyword is valid.
012: The protocol keyword must have a frame type. Entry ignored.
Source: TRXNET-DOS.LAN
Explanation: The PROTOCOL keyword entry is incomplete.