User Guide
768 System Messages
System Messages
103-000150-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
Action: Replace the network board with one that works. For information about a
specific error code, search the Error Codes online documentation (http://
www.novell.com/documentation/lg/nwec/docui/index.htm).
223: The board must be placed in a 16-bit slot.
Source: NE2000-NW.LAN
Explanation: The network board was placed in an 8-bit slot.
Action: Move the network board to a 16-bit slot.
224: This board is configured as an NE1000.
Source: NE2000-NW.LAN
Explanation: The board is responding with an NE1000 ROM signature.
Action: Make sure the I/O port settings on the network board match the I/O port
settings in the AUTOEXEC.NCF file. If the settings match, replace the
network board.
233: The adapter detected a duplicate station during the insertion process.
Source: CNTR2000.LAN
Explanation: Another network board is using the same node address.
Action: Use a different node address.
235: The adapter cable was disconnected during the insertion process.
Source: CNTR2000.LAN
Explanation: The network board could not access the network because the cable was
disconnected.
Action: Securely fasten the cable links, reboot the workstation, and reload the driver.
236: The ring was beaconing during the insertion process.
Source: CNTR2000.LAN
Explanation: The network board could not access the network because it is set at an
incorrect data rate.
Action: Set the network board to the correct data rate.