User Guide

772 System Messages
System Messages
103-000150-001
August 29, 2001
Novell Confidential
Manual 99a38 July 17, 2001
The board's IRQ cannot be found.
Source: CNEAMD.LAN
Explanation: The interrupt setting is incorrect or is not available.
Action: Make sure the interrupt setting on the network board matches the setting in the
configuration file.
Also, refer to the manufacturer's instructions for configuring the network
board.
If the board still does not respond, replace it with one that works.
The board's memory failed the memory test.
Source: CNE2.LAN, CNE2000.LAN, CNE3200.LAN
Explanation: The network board's memory failed.
Action: Make sure the port and interrupt settings on the network board match the
settings in the configuration file.
Also, refer to the manufacturer's instructions for configuring the network
board.
If the board still does not respond, replace it with one that works.
The board's PORT cannot be found.
Source: CNEAMD.LAN
Explanation: The port address setting is incorrect or not available.
Action: Make sure the port setting on the network board matches the setting in the
configuration file.
Also, refer to the manufacturer's instructions for configuring the network
board.
If the board still does not respond, replace it with one that works.
The cable might be disconnected on the board.
Source: CNEAMD.LAN,
Explanation: The network cable is disconnected, or heavy traffic on the wire is delaying
packets from being sent.
Action: Check the cable to ensure the connection is good. If the cable connection is
good and the problem persists, network traffic might be heavy.