Operating Instructions and Installation Instructions

Replacement of the fluorescent lighting
First take the plug from the wall socket or switch
off the power group. Let the lamp cool down
sufficiently before replacing it.
Open the bottom plate and remove the grease
filter from the hood.
Loosen the screws that keep the glass plate at
its place.
Tilt down the glass plate C to make it pass the
filter holder. If necessary, lightly press side D
for easily tilting down.
Turn the fluorescent lamp a quarter turn to
remove it from its holder.
Put back the new lamp in the holder and turn
it again a quarter of a turn until you hear a soft
‘click’.
Model Hood 680
Reference Novy 680.025
Type of lamp LUMILUX T8 L15 W/840
Model Hood 686
Reference Novy 686.025
Type of lamp LUMILUX T8 L16 W/840
Back to the initial position
Tighten everything again to the initial position.
IMPORTANT! When the glass panel (A) is
placed back, the glass panel has to be pushed
over the filter holder so its fixed (fig. 3.3).
Place the grease filter back in its support
Electrical connection
Electrical output: electrical cord + plug with
ground. To be plugged into socket with ground.
Check for compatibility with information on type
plate (behind filter).
Socket must be within reach.
Changes or replacement of the electrical cord
should be performed by a professional only.
Dimensions: p. 18
Electrical scheme: p. 19-20