INSPECTION
1. Inspection of PLUG & PLAY communication
1-1. A construction of System
This system should be connected as shown below.
1-2. Starting method
1) Input Signal
Input signal must be separate sync. Timing is the signal whose vertical synchronization frequency is
between 55Hz and 25kHz.
Horizontal synchronization frequency should be set to 31.5kHz.
2) Power ON procedure
ž First, put the floppy disk for PnP Inspection into PC and turn on PC.
ž Turn on Fixture.
ž Make sure that fixture s LED turns on and off.
ž Turn on signal generator and monitor.
3) Starting PC Software
ž Inspection of PnP communication
To check the PnP communication, for N9702, EDID file name is N9702.
Type P N9702 on DOS command line and press return key.
ž Writing EDID to EEPROM and inspection of PnP communication
To write EDID to EEPROM and check the PnP communication of N9702, type WP N9702
on DOS prompt line and press return key.
Monitor
Fixture
Signal Cable
R
G B H V
Power Cable
Power Cable
Signal Generator
[
TEST PROGRAM
PART No. 599910408
Program Disk
PC