Datasheet
Electrical Characteristics: (At “Maximum Ratings” and Specified Case Temperatures)
Parameter Symbol Test Conditions Min Typ Max Unit
Peak Off−State Current I
DRM
,
I
RRM
V
DRM
& V
RRM
= Max Rating,
T
J
= +100°C, Gate Open
− − 2.0 mA
Maximum On−State Voltage (Peak) I
HO
T
C
= +25°C − − 50 mA
DC Gate Trigger Current I
GT
Anode Voltage = 12V, R
L
= 30Ω,
T
C
= +25°C
− − 30 mA
DC Gate Trigger Voltage V
GT
Anode Voltage = 12V, R
L
= 30Ω,
T
C
= +25°C
− − 2.0 V
Gate Controlled Turn−On Time t
gt
I
GT
= 150mA − 2.5 − μs
Critical Rate of Rise of
Off−State Voltage
dv/dt
(Critical)
Gate Open, T
C
= +100°C − 100 − V/μs
.200 (5.08) Max
.562
(14.28)
Max
1.193
(30.33)
Max
.453
(11.5)
Max
CathodeGate
Anode
1/4−28 UNF−2A