Datasheet

NTE5679
TRIAC − 600V, 40A
Description
The NTE5679 TRIAC may be gate triggered from a blocking to conduction state for either polarity of
applied voltage and is designed for AC switching and phase control applications such as speed and
temperature modulation controls, lighting controls, and static switching relays. The triggering signal
is normally applied between the gate and MT
1
.
Electrical Characteristics: (All measurements are at T
A
= +25°C, 60Hz with a resistive load unless
otherwise specified)
Repetitive Peak Blocking Voltage (Note 1), V
DRM
600V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RMS On−State Current (Conduction Angle of 360°, T
C
= 0° to +125°C), I
T(RMS)
40A. . . . . . . . . . . .
Peak Off−State Current (V
DRM
= 600V, Gate Open, Note 1), I
DRM
T
C
= +25°C 200mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T
C
= +125°C 5mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak One−Cycle Surge Current, I
TSM
50Hz 335A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
60Hz 400A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Non−Repetitive RMS Surge On−State Current for Fusing (I
GT
= 500mA, 8.3ms), I
2
t 664A
2
sec. . . .
Maximum DC Gate Trigger Current (V
D
= 12V, Quad I, II, III), I
GT
100mA. . . . . . . . . . . . . . . . . . . . . .
Maximum DC gate Trigger Voltage (V
D
= 12V, Quad I, II, III. Note 2), V
GT
T
C
= +25°C 2.5V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T
C
= +125°C 0.2V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak On−State Voltage (I
T(RMS)
= 40A, T
C
= +25°C, Note 1), V
TM
1.8V. . . . . . . . . . . . . . . . . . . . . . .
DC Holding Current (gate Open, Note 1, Note 3), I
H
120mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak Gate Trigger Current (Pulse Width 10µs), I
GTM
4A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak Gate Power Dissipation (Pulse Width 10µs), P
GM
40W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Average Gate Power Dissipation, P
G(AV)
800mW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Minimum Critical Rate of Rise of Off−State Voltage (V
DRM
= 600V, Gate Open, Note 1), dv/dt
T
C
= +100°C 375V/µs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T
C
= +125°C 250V/µs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Minimum Critical Rate of Rise of Commutation Voltage (Note 1), dv/dt
(c)
(V
DRM
= 600V, I
T(RMS)
= 40A, Commutating di/dt = 21.6A/msec, Gate Unenergized) 4V/µs
Maximum Rate of Change of On−State Current (I
GT
= 200mA, Rise Time = 0.1µs), di/dt 150A/µs.
Maximum Gate Controlled Turn−On Time (I
GT
= 500mA, Rise Time = 0.1µs), t
gt
5µs. . . . . . . . . . . .
Operating Temperature Range, T
J
0° to +125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage Temperature Range, T
stg
−20° to +125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note 1. For either polarity of MT
2
with reference to MT
1
terminal.
Note 2. For either polarity of gate voltage (V
GT
) with reference to MT
1
terminal.
Note 3. Initial On−State Current = 400mA (DC).