Safety Information

Page 43 of 60 Report No. WUX202107133461UL
UL 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1C
5.4.9
TABLE: Electric strength tests
P
Test voltage applied between:
Voltage shape
(Surge, Impulse, AC,
DC, etc.)
Test voltage (V)
Breakdown
Yes / No
Line/neutral and Earth
DC
2500
No
Diferent polarity of AC mains
DC
2500
No
Line/neutral and accessible enclosure
DC
4000
No
Primary AC input and accessible secondary
part
DC
4000
No
Transformer primary winding and secondary
DC
4000
No
Supplementary information: