Safety Information

Page 50 of 60 Report No. WUX202107133461UL
UL 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC62368_1C
manufacturer/type
and fault
condition
Charging
voltage (V)
Charging
current (A)
Temp.
(
o
C)
Supplementary information:
Abbreviation: SC= short circuit; OC= open circuit; MSCV= maximum specified charging voltage; MSCC=
maximum specified charging current; HSCT= highest specified charging temperature; LSCT= lowest
specified charging temperature
Q.1
TABLE: Circuits intended for interconnection with building wiring (LPS)
P
Output
Circuit
Condition
U
oc
(V)
Time (s)
I
sc
(A)
S (VA)
Meas.
Limit
Meas.
Limit
5V dc
output
Normal
5.10
3
3.8
8
17.7
100
Single fault
0
0
0
8
0
100
Supplementary Information: