Page 57 of 60 Report No. WUX202107133461UL
TRF No. IEC62368_1C
Annex DVA
(G.4.3)
Where a fuse is used to provide Class 2 or
Class 3 current limiting, it is not operator-
accessible unless it is non- interchangeable.
N/A
Annex DVA
(G.5.3)
Power distribution transformers distributing
power at 100 volts or more, and rated 10 kVA or
more, require special transformer overcurrent
protection.
N/A
Annex DVA
(G.5.4)
Motor control devices are required for cord-
connected equipment with a mains-connected
motor if the equipment is rated more than 12 A,
or if the equipment has a nominal voltage rating
greater than 120 V, or if the motor is rated more
than 1/3 hp (locked rotor current over 43 A).
N/A
Annex DVA
(Annex M)
For ITE room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes have a battery disconnect means
that may be connected to the ITE room remote
power-off circuit.
N/A
Annex DVA
(Q)
Wiring terminals intended to supply Class 2
outputs according to the NEC or CEC Part 1are
marked with the voltage rating and “Class 2” or
equivalent; marking is located adjacent to the
terminals and visible during wiring.
N/A
Annex DVB
(1)
Additional requirements apply for equipment
used for entertainment purposes intended for
installation in general patient care areas of
health care facilities.
N/A
Annex DVC
(1)
Additional requirements apply for equipment
intended for mounting under kitchen cabinets.
N/A
Annex DVE
(4.1.1)
Some equipment, components, sub-assemblies
and materials associated with the risk of fire,
electric shock, or personal injury have
component or material ratings in accordance
with the applicable national (U.S. and Canadian)
component or material requirements.
Components required to comply include:
appliance couplers, attachment plugs, battery
back-up systems, battery packs, circuit
breakers, communication circuit accessories,
connectors (used for current interruption of non-
LPS circuits), power supply cords, direct plug-in
equipment, electrochemical capacitor modules
(energy storage modules with ultra-capacitors),
enclosures (outdoor), flexible cords and cables,
fuses (branch circuit), ground-fault current
interrupters, interconnecting cables, data
storage equipment, printed wiring, protectors for
communications circuits, receptacles, surge
protective devices, vehicle battery adapters,
wire connectors, and wire and cables.
P