Machine Set-Up
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED
BEFORE MAKING ANY ADJUSTMENTS
!
!
Fitting the brushes
Featuring the Nulock brush system.
The brush is simply pushed and twisted to lock, making tting and removal a simple process.
Slide the brush / pad under the brush deck (Fig 6).
Fit the brush / pad onto the Nulock drive chuck, twist to lock
the brush / pad in place (Fig 7).
Only use manufacturer supplied brushes.
This machine requires a 400mm brush or a 360mm pad.
Fitting the Floor Tool
The oor tool has been designed for quick tting, allowing easy squeegee blade replacement and a safety knock-off
feature if the oor tool gets snagged, whilst in transit.
Swing the oor-tool carrier to the side of the machine
(Fig 8).
Secure to the carrier using the
two knobs tted to the oor-tool
carrier (Fig 9) - (Fig 9a).
Do not over tighten the retaining
knobs.
Fig 6
Fig 7
Fig 8
Fig 9
Fig 9a
Safety gloves are recommended for the changing of used brushes.
Note:
It is easier to t the oor-tool if the weight of the machine is
resting on the brush. Ensure the brush is tted rst.