Operation Manual

233970 (Page 34) 10/11 (A13)
Regular Maintenance
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED
PRIOR TO ANY MAINTENANCE OPERATION
! !
After use, empty waste-water tank using
emptying hose and ush-out with clean
water.
A
Remove the two hoses to disconnect the separator from the
machine (Fig 28).
Lift off the separator. The separator has a sealing-rubber
which should be examined at every clean-down (Fig 29).
Rinse using clean water.
NOTE:
Avoid over tightening the clean water draining cap.
The TTB 1840 has been designed with ease of use in mind, this included easy stripping-down and cleaning.
Remove the two lters clipped into the separator and ush with clean water (Fig 30)(Fig 30a).
Replace by tting the rear of the lter rst then clipping the front to lock in place (Fig 31) (Fig 32).
Disconnect and remove the
battery before proceeding with
tank removal (Fig 33).
Once emptied the top
waste-water tank can simply be
lifted off. (Fig 33a).
The clean-water tank can be drained via the yellow cap tted
to the left hand side of the machine. The cap has a rubber
seal and might require a spanner to remove. (Fig 34).
Fig 28
Fig 29
Fig 30 Fig 31
Fig 32
Fig 33
Fig 34
A
Fig 30a
Fig 33a