Operation Manual
Fault Finding - Dry - Wet - Declaration Document
This machine can be used for wet and dry pick up.
Dry Mode maintenance / fault nding
If the vacuum cleaner stops working switch off and remove the plug from the wall before
investigating were the fault lies.
If the vacuum cleaner will not pick up any debris from the surface, switch off and remove the plug from the wall,
inspect the oor tool, wands and hose for blockages, if no blockages are found, the dust bag may be full if the
dust bag is not full the lter may be blocked.
Wet mode / fault nding
If the vacuum cleaner stops working switch off and remove the plug from the wall before
investigating were the fault lies.
If the vacuum cleaner has a blockage and will not pick up liquid, switch off and remove the plug from the wall,
has the oat valve operated, this will shut off the suction and the pitch of the vacuum motor will change Remove
the power head and empty the liquid out of the container, if the container is empty, check that the oor tool
wands and hose are not blocked.
After use always inspect the machine for damage.
13
EU DECLARATION
OF
CONFORMITY
We hereby declare under our sole responsibility that the
following equipment ful ls all the relevant provisions of the
following EU Directives:
Machine Description: Vacuum Cleaner
Type: CVC, WV, WX series
Relevant standards upon which conformity is declared
include:
IEC60335-1:1991+A1+A2
IEC60335-2-2:1993+A1+A2
IEC60335-2-69:1997+A1
EN 55014-1 2001 +A1 2001, +A2 2002
EN 55014-2 1997 + A1 2001 (Cat II)
EN 50366 2003 + A1 2006
A technical construction le for this equipment is retained at
the manufacturer’s address under the authorisation of the
following signatory:
Signed:
Date: 01 /01/2013
Numatic International Limited,
Chard , Somerset.
TA20 2GB
www.numatic.co.uk
GB
13
Position: Technical ManagerName:Allyn Boyes
Manufactured by: Numatic International Limited
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC