User's Manual

12 | Page
Proprietary and Confidential Revised 10-11-11
Alarm: Alarm magnet mode configures the device to initiate an alarm message operation. In this
mode the magnet is recognized by the SXL1 but does not trigger “sleep mode. When the device
detects the magnet inserted for at least 15 seconds, the device will arm itself for alarm on magnet
removal. The alarm is triggered on magnet removal only, not insertion. The dialog “GPS FIX?”
checkbox is used to instruct the SXL1 to send an alarm message with or without GPS location. If the
checkbox is unchecked, the alarm message will be sent immediately with null (zero) data in the GPS
fields. If the SXL1 has not detected motion since it’s GPS fix it will send those coordinates instead of
null data.
Subsequent messages may also be configured that will follow the initial alarm message. The
subsequent messages will also contain or not contain GPS data depending on the GPS FIX
checkbox. If a quantity of 31 subsequent messages is entered, the alarm will be considered infinite
until the alarm is reset.
Cut Wire / Dry Contact Operation: The SXL1 does not support the Cut Wire functionality of the
SX1.
Testing Tab
The “Testing” tab supports field evaluation and testing of devices using a variety of manual
commands and queries. The Testing tab provides the interfaces to force message transmissions or
query GPS or evaluate engineering data. In order to receive the on-air messages the SXL1 must be
outside or taken outside immediately after clicking the button. To query the GPS, the SXL1 must be
outside when the query is initiated. The tab dialog window appears as shown below: