Installer Programmable Features (cont’d)
Feature #11 - Manual Transmission Mode
On (press “start” 1 time to program)
Off (press “start” 2 times to program) - DEFAULT
This feature changes the parameters of the system’s remote start operation to be suitable for
manual transmission-equipped vehicles via a “setup” procedure which must be followed upon exit-
ing the vehicle to ensure the transmission is in neutral.
Feature #10 - Turbo Timer
Off (press “start” 1 time to program) - DEFAULT
Run 1 Minute (press “start” 2 times to program)
Run 2 Minutes (press “start” 3 times to program)
Run 3 Minutes (press “start” 4 times to program)
This feature, the operation of which is described on page 7, when turned on
congures the system to automatically keep the engine running briey after the key is turned off.
This operation is designed specically for vehicles with turbocharged engines. NOTE: This feature
is dependent on the proper wiring of the neutral safety circuit.
Feature #9 Remote Start Lock Control
Off (press “start” 1 time to program) - DEFAULT
Lock After Start (press “start” 2 times to program)
Unlock before start (press “start” 3 times to program)
Unlock Before RS & Lock After RS (press “start” 4 times to program)
This feature allows for OEM alarm/lock control in relation to remote start operations thus eliminat-
ing extra wiring for OEM alarm control.
Feature #8 - Door Lock/Unlock Outputs
0.8 Second Outputs (press “start” 1 time to program) - DEFAULT
3 Second Outputs (press “start” 2 times to program)
Double Pulse Unlock Output (press “start” 3 times to program)
Total Closure Lock Output (press “start” 4 times to program)
This changes the system’s doorlocking outputs to suite different vehicle requirements. The total
closure setting provides a 28 second lock pulse (press LOCK or UNLOCK is during the pulse to
stop it) and a 0.8 second unlock pulse.
Feature #13 - Virtual Alarm
On (press “lock” button to program)
Off (press “unlock” button to program) - DEFAULT
Off / 1-Button Unlock Only (press “trunk” button to program)
This feature converts the system into a Security/Remote Start System by enabling antitheft
alarm-oriented operations and features. OPTIONAL MODULES MAY BE REQUIRED. The “Off /
1-Button Unlock Only” setting disables the LOCK function from 1-button remotes.
Feature #12 Data Port Protocol
Green: DBI, Black: DBI (press “lock” button to program)
Green: iData, Black: iData (press “unlock” button to program)
Green: DBI, Black: iData (press “trunk” button to program)
Green: iData, Black: DBI (press “start” button to program)
Auto-Detect: (press “lock” & “unlock” buttons to program) - DEFAULT
This feature determines which data protocol is used on each data port. By default, this feature
shouldn’t need to be changed. With everything installed and connected to the data ports, upon the
rst remote start attempt, each port will auto-detect the type of device connected and choose the
proper protocol. This can also be congured manually. NOTE: When a BLADE is inserted, the
black data port automatically switches to iData protocol.
12