User's Manual
Table Of Contents
Installer Programmable Features (cont’d)
Feature #5 - Light Relay Function (3DB) / Sat. Port Green Wire Function (non-3DB)
Dome Light Output (press START 1x to program)
Start (press START 2x to program)
Ignition Output (press START 3x to program)
Accessory Output (press START 4x to program)
Status (press START 5x to program)
Light Flash (press START 6x to program)
This output can be programmed to perform any functions listed above� 3DB models
utalize a built in relay� Non-3DB models use a 250ma negative output on the satalite port�
Feature #7 - Starter Cranking Time
0.75 Second (press START 1x to program)
1.00 Second (press START 2x to program)
1.5 Seconds (press START 3x to program)
2.25 Seconds (press START 4x to program)
3 Seconds (press START 5x to program)
Average (press START 6x to program)
This feature determines the crank time of the 1st start attempt when in “Tachless” mode�
If the engine doesn’t start on the rst attempt, it will retry up to 3 more times extending
the crank time by an additional 0�2 second with each attempt� The “Average” setting will
sample the last 8 cranks (by ignition key) and average the crank time automatically for
increased accuracy�
Feature #8 - Door Lock/Unlock Outputs
0.8 Second Outputs (press START 1x to program)
3 Second Outputs (press START 2x to program)
Double Pulse Unlock Output (press START 3x to program)
Total Closure Lock Output (press START 4x to program)
This changes the system’s doorlocking outputs to suite different vehicle requirements� The
total closure setting provides a 28 second lock pulse (press LOCK or UNLOCK is during
the pulse to stop it) and a 0�8 second unlock pulse�
Feature #9 - Remote Start Lock Control
Off (press START 1x to program)
Lock After Start (press START 2x to program)
Unlock Before Start (press START 3x to program)
Unlock Before Start & Lock After Start (press START 4x to program)
Lock After Engine Off (press START 5x to program)
This feature allows for OEM alarm/lock control in relation to remote start operations thus
eliminating extra wiring for OEM alarm control�
Feature #6 - Blue Satellite Port, Blue Wire Function
Ignition (press START 1x to program)
Status / GWR (press START 2x to program)
Defrost 0.8 sec Pulse (press START 3x to program)
Defrost 10 min Pulse (press START 4x to program)
Pulse After Engine Off (press START 5x to program)
Horn (press START 6x to program)
This determines the function of the Blue wire on the Blue satellite relay port�
The Status setting turns on briey before the Ignition output and stays on during remote
start mode� The other pulse settings give a 0�8 second pulse under the selected condi-
tion� Defrost Pulse will send a pulse after start only when the cabin temperature is below
freezing (32 degrees F / 0 degrees C)�
16