Use and Care Manual

Page 1
MODEL 744NT
RECESSED
FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
To clean trim ring / baffle: Vacuum with a soft brush attachment
or remove trim ring / baffle and clean with a soft cloth and mild
soap or detergent. Dry thoroughly before reinstalling.
To clean inside of housing: Remove trim ring / baffle and vacuum
inside of housing with a soft brush attachment.
OPERATION
The fan and light can be operated using various combinations
of on/off switches and timer controls:
Fan and light controlled with single on/off switch
Fan and light controlled with separate on/off switches
Fan controlled with on/off switch - light with dimmer switch
Fan controlled with timer control
Do not use a speed control to operate the fan in this unit.
See “Connect Wiring” section for various wiring options.
CLEANING
MAINTENANCE
WARRANTY
NUTONE ONE YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of its products that such products
will be free from defects in materials or workmanship for a period of one year from the
date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IM-
PLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, NuTone will, at its option, repair or replace, without charge,
any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES.
This warranty does not cover (a) normal maintenance and service or (b) any products
or parts which have been subject to misuse, negligence, accident, improper mainte-
nance or repair (other than by NuTone), faulty installation or installation contrary to
recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE
THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE
SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify NuTone at the address or telephone
number stated below, (b) give the model number and part identification and (c) describe
the nature of any defect in the product or part. At the time of requesting warranty service,
you must present evidence of the original purchase date.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
Motor is permanently lubricated. Do not oil or disassemble motor.
See “Service Parts” section for a list and illustrations of service parts.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Interrupter) - protected branch cir-
cuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. Install this unit in a flat ceiling only.
10. For use in non fire rated installations only.
11. Not for use in environmental air handling spaces.
12. CAUTION - RISK OF FIRE: 75W MAX. LAMP. Use R30,
BR30, PAR30L, or PAR30LN lamps only (75W Max.). For
wet locations (tub or shower) - use PAR30L or PAR30LN
(75W Max.) lamp only. Use no other lamp types. Do not
install a lamp indentified for use only in enclosed luminaries.
13. This unit must be grounded.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, use the cardboard protector (provided) to
keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further infor-
mation and requirements.

Summary of content (8 pages)