Specification
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
SPECIFICATION SHEET
51K 99045573A
MODEL 791LEDNTM
VENTILATION FAN
WITH LED LIGHT
TYPICAL SPECIFICATION
Ventilation Fan with LED Light unit shall be NuTone Model
791LEDNTM.
Unit shall have galvanized steel housing with integral
mounting holes. It shall be ducted to a roof or wall cap.
Blower assembly shall be removable and have a
permanently lubricated motor.
Light fixture assembly shall be plug-in, removable and
includes built-in LED lighting.
Air delivery to be no less than 100 cfm and sound level
no greater than 1.5 sones. Air and sound ratings shall be
certified by HVI.
Unit shall be U.L. Listed for use in insulated ceilings (Type
I.C.)
DESCRIPTION
BLOWER:
• Plug-in permanently lubricated motor
• Polymeric blower wheel
• Can be used to comply with ASHRAE 62.2, LEED, ENERGY
STA R
®
for Homes and CA Title 24
HOUSING:
• Rugged, 25-gage galvanized steel construction
• Fits in 2" x 6" construction
• Pre-located mounting holes for quick, accurate installation
• Tapered, polymeric duct fitting with built-in backdraft damper
for easy, positive duct connection and no metallic clatter
LIGHTING / GRILLE:
• Highly efficient, 9 Watt, integrated LED
• LED lasts up to 25,000 hours
• Unique, low profile, perimeter-lit design for wide light pattern
• Even lens diffusion eliminates hotspots
TO OPERATE FAN AND LIGHT:
• Use only an ON/OFF or timer switch to operate the fan.
• Use only an ON/OFF switch, timer switch or relay-switch
to operate the LED light.
• The LED light cannot be used with a dimmable switch.
• Both the fan and LED light can be put on one switch.
Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
NOTE: For installation in flat ceilings only.
U.L. Listed for use in insulated ceilings (Type I.C.)
Use supply wiring rated for at least 90° C.