Spec Sheet

Broan Hartford, Wisconsin www.nutone.com 888-336-3948
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
SPECIFICATION SHEET
02B 99045878B
MODEL AERN100SN
INVENT
TM
SERIES
DECORATIVE FAN / LIGHT
DESCRIPTION
BLOWER:
Plug-in, permanently lubricated motor - engineered for
continuous operation
Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
Low RPM for quiet operation
HOUSING:
Rugged, 26 gauge, galvanized steel construction
Polymeric, 4” duct connector with tapered sleeve and no
metallic clatter
5-3/4” height allows for 2” x 6” ceiling installations
Sturdy, easy, four-point mounting directly to joist
LIGHT FIXTURE:
Consumer-validated design
Glass and steel construction
Corrosion-resistant, satin-nickel finish
Frosted glass shade
Light fixture is plug-in and removable
Dimmable,18.5-Watt intergrated LED lighting for energy
efficiency
3000K color temperature provides soft white light - ideal for
bathroom illumination
LED lasts up to 25,000 hours for maintenance-free
convenience
CONTROLS (Purchase separately):
Refer to NuTones catalog for a complete line of accessories to
effectively adapt these fans to your construction requirements.
DIMMING CONTROLS :
May not be compatible with all dimmer controls
Each application is unique and various factors such as
load, common neutrals or other electrical products on the
circuit can, in certain instances, cause variance in system
performance.
Dimmer model numbers vary slightly depending on color,
packaging type, etc. such that variations of Model numbers
may be suitable. Consult dimming system manufacturer for
additional support in operation
* For a list of compatible controls, see NuTone.com.
For installation in flat ceilings only.
U.L. Listed for use in insulated ceilings (TYPE I.C.)
3-Year Warranty
TYPICAL SPECIFICATION
Fan / Light shall be NuTone Model AERN100SN.
Fan / Light shall have corrosion resistant galvanized steel
housing with four-point mounting capability. It shall be ducted to
a roof or wall cap using 4” round ductwork.
Blower assembly shall be removable, have a centrifugal-type
blower wheel and a permanently lubricated motor designed for
continuous operation.
Non-metallic damper/duct connector shall be included.
Light fixture assembly shall be plug-in, removable and include a
frosted glass shade. It will have a corrosion-resistant base with
satin-nickel finish.
LED shall be 18.5-Watt with 3000K color temperature and 800
lumen output (min.).
Air delivery shall be no less than the airflow values and no
greater than the sound level values listed in the HVI Performance
Specifications provided in this specification (see following chart).
All air and sound ratings shall be certified by HVI.
Ceiling Ventilator shall be cULus Listed for use in insulated
ceilings (Type I.C.).
JA8-2019