ADA Wiring Instructions

1
ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR SINGLE BLOWER RANGE HOODS
WITH LED MODULES AND ROCKER SWITCH CONTROL
WARNING
!
For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service
disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards. Also, it is recommended to wear safety glasses and gloves.
ACCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS
Remove filters from the hood and set them aside.
Remove the wiring cover (shaded part in illustration below)
retaining screw. Slide the wiring cover out of the hood and set it
aside with its screw.
Remove and set aside the 4 front screws retaining the electrical
panel cover plate to the hood. Open the electrical panel cover.
NOTE: The illustrations in this procedure are generic; some hood details may slightly differ from the hood you have on hand but the
procedure itself applies to all single blower range hoods listed in this document.
Wiring cover
screw
Cut, close to the switches, the RED wire and the BLACK wires
from motor switch terminals, and the BLUE wire from the light
switch terminal.
MOTOR SWITCH
TERMINALS
LIGHT SWITCH
TERMINALS
A
BLACK WIRE
BLUE WIRE
RED WIRE
Push the end of the BLUE wire through the electrical panel cover
plate opening. Pull the RED and BLACK motor wires through the
electrical panel cover plate opening.
HR0279
1104770B
Close the electrical panel cover using 4 screws previously
removed in step
.
HO0409
THIS PROCEDURE APPLIES TO THE FOLLOWING RANGE HOOD SERIES
Broan Series: BCSEK1, BQSEN1 and CRSF1
NuTone Series: AHSL1, AVSF1, AVSF1-2, NCSEK1 and NQSEN1
Venmar Chef Series: VCQSEN1