Use and Care Manual

10
INSTALLATION IN NEW CONSTRUCTION (CONT'D)
CI390 ELECTRAVALVE™
ELECTRIFIED INLET INSTALLATION
(CI395RK ROUGH-IN)
B Refer to top figure at right. Fasten the mounting plate to a stud
within three studs (48") of an electrical outlet box. Measure
and mark the wire 10" from the plug (A). Feed the wire
through the top hole in the mounting plate (just above the
circular opening). Snap the molded plug into the mounting
plate as pictured (B). This will keep it secure and out of
harm’s way during drywalling and finishing. Line up the wire
at the previously measured 10" mark with the strain of relief
channel on the back of the mounting plate. Secure it in place
with the supplied wire tie (C).
C Refer to top figure at right. Run the inlet wire to the adjacent
electric box. If you must run wire through a stud, drill directly
through the center of the stud (D).
D Refer to bottom figure at right. Place the exposed ends of
the two wires into the electrical box through a strain relief
channel (E). Tighten the strain relief channel (do not
overtighten) on the white sheathing leaving 1⁄2" of this
sheathing exposed inside of the outlet box. Fold the 6" of
BLACK and WHITE wire into the outlet box. Leave the wires
to be connected by the electrician when plug receptacles
are being installed.
E Once drywall and finishing processes have been completed,
remove molded plug from mounting plate (with the aid of a
slot screwdriver) and snap it into the wing slot at the back of
the inlet (F).
NOTE: molded plug fits one way only, with the narrow
opening at the top.
Insert inlet into the mounting plate and secure inlet to
mounting plate with screws provided.
NOTE: All electrical devices such as the electrified inlet should
be reported to the construction electrician for listing on
the inspection report for building inspection purposes.
NOTE: Plumb inlet to tubing using NuTone Model CF382S
90° ELL fitting.
CAUTION
Power tools such as routers are not recommended
for use with the inlet installation, as removal of
drywall with these devices may cause damage to
the mounting plate and/or inlet plug.
WARNING
!
All location and installation direct connect
electrified wall valves must conform with all local
and municipal building codes.
D
AE0038A