Use and Care Manual

20
CI365 VACPAN™ INSTALLATION INSTRUCTIONS (CONT'D)
Refer to illustration at bottom of page.
IN WALL INSTALLATIONS
CI365 VACPAN can be installed between wall studs in side
walls.
CI365 VACPAN should be located tight to one side in stud
space.
Once the CI365 VACPAN location is determined, cut a
6¾” long x 1¾” high slot in the wall and baseboard to accept
the CI365 VACPAN.
The 2” x 4” wall bottom plate between the 2 studs must be
removed. This can be achieved from below using a hole saw.
In new home construction, the bottom wall plate can be
removed directly. A 6¾” length of 2 x 4 can be used as a
temporary rough in block, that will force all trades to finish
around, leaving a slot for the CI365 VACPAN.
Floor contractor must run flooring under block.
Run vacuum tube piping and low voltage wire from the main
line to CI365 VACPAN location.
Access for final piping connections must be made.
ACCESS FROM BELOW
If access is available from below, cut an access hole through
the subfloor underneath the wall between the studs, positioned
so that final piping connections can be made by reaching
through the access hole.
ACCESS THROUGH WALL
Access can be made through the finished wall. Cut a
2¾” x 3½” access hole, positioned so that final piping
connections can be made by reaching through the access
hole. A generic cover plate can be used to cover the hole after
installation (sold separately).
Attach low voltage wires to CI365 VACPAN terminal
connections marked “low voltage only”.
Slide CI365 VACPAN into mounting slot and secure to toe
kick using two no. 6 screws provided.
Reach through access hole and make final fitting
connections.
CI365 VACPAN™
IN WALL INSTALLATIONS
COVER PLATE
CF382S
UNIVERSAL
SHORT 90° ELBOW
AH0007A