Installation Guide

8
Function Operation LED Indication Troubleshooting
Power Button
(left)
Reset Button
(Right)
System On/
Off.
Press. Displays solid
green.
Reset 4
Hour System
Timer
(Before
Timer
Expires).
Single quick
press.
LED will flash
green quickly 2
times to indicate
timer is now
reset to 4 hours.
Low
Repellent.
LED will
continually
fade on and off
slowly.
Reset
195 Hour
Repellent
Timer.
Press and
hold for 5
seconds (can
be reset at
any time).
LED will Flash 5
times then turn
solid green.
Low Voltage
Indication.
LED will flash
once every
4 seconds.
This warning
indicates voltage
of system is low
and system may
not be functioning
fully.
Controller Operation
Short Circuit Protection/Troubleshooting
There are two forms of protection for this fault mode to protect product from
damage. Potential issues include improper fixture connection, cut wires, or
shorted wire connections.
1. LED on the controller will continually flash rapidly. System installation
needs to be inspected. To reset, unplug for 30 seconds and reconnect
controller power cord from outlet.
2. LED on the controller will be illuminated solid green but all fixture
indication LEDs will be OFF. System installation needs to be inspected
and internal fast acting fuse in controller needs to be replaced. Short
circuit must be resolved prior to fuse replacement. Disconnect power and
remove four screws from the back of controller to gain access fuse holder.
Replace with provided fuse (5Amp Littelfuse 0312005.HPX).