WWW.BROAN-NUTONE.COM WWW.BROAN.CA WWW.NUTONE.
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 Cleaning and Maintenance . . . . . . . . . . . . . . . . . .7 Motor Grease Filter(s) Non-Ducted Recirculation Filter(s) Fan Blade Stainless Steel Cleaning Painted Finish Cleaning Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23 INSTALLATION MANUAL TABLE OF CONTENTS Recommended Tools and Accessories for Installation . . . . . . . .
READ AND SAVE THESE INSTRUCTIONS ! Intended for domestic cooking only ! INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. In U.S.A., register your product online at www.Broan-NuTone.com In Canada, register your Broan product online at www.broan.ca In Canada, register your NuTone product online at www.nutone.ca ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Use this unit only in the manner intended by the manufacturer.
! WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fan frequently. Grease should not be allowed to accumulate on fan, filters or in exhaust ducts. d) Use proper pan size.
Operation Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as follows: BKSA2 AND NKSA2 SERIES BLOWER SWITCH I • II Turns blower on to LOW speed. Turns blower OFF. Turns blower on to HIGH speed. LIGHT SWITCH I • II Turns light on in LOW intensity. Turns light OFF. Turns light on to HIGH intensity.
BKDD1, BKDF1 AND NKDF1 SERIES BLOWER BUTTON When blower is OFF, press this button to turn ON the blower at the last saved speed. If there was no speed saved, the blower will be set on LOW speed. NOTE: When LOW speed is activated from OFF, the blower starts on MEDIUM speed for a very short lapse of time, and then resume to LOW speed. To change the blower speed, press on this button again until the desired speed is reached (from LOW to MEDIUM to HIGH speed to OFF).
Cleaning and Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit. MOTOR The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan blade should also be replaced. GREASE FILTER(S) The grease filter(s) should be cleaned frequently. Use a warm dishwashing detergent solution. Clean all-metal filters using a non-phosphate detergent.
For ADA compliance installation guidelines, please type the model number into our website. Recommended Tools and Accessories for Installation • • • • • • • • • • • • • • • • Measuring tape Phillips screwdriver no.
Contents Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: BKDF1 and NKDF1 Series BKSM1, CKSL1 and NKSH1 Series (2) SHIELDED HALOGEN BULBS (50W, GU10) (1) 3¼” X 10” DAMPER ASSEMBLY (FIND INSIDE OF HOOD) (2) GREASE FILTERS (2) GREASE FILTERS (INSTALLED ON HOOD) EZ1 COMPONENTS Use this template for marking; do not attempt to cut out the ducting hole through it.
BKSR1 Series BKDD1 Series * FIND INSIDE OF HOOD (2) SHIELDED HALOGEN BULBS (50W, GU10) (2) GREASE FILTERS (1) 3¼” X 10” DAMPER ASSEMBLY* (2) GREASE FILTERS * FIND INSIDE OF HOOD EZ1 COMPONENTS Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
BKSA2 and NKSA2 Series BKDF130SSK * FIND INSIDE OF HOOD (1) GREASE FILTER (1) 3¼” X 10” DAMPER ASSEMBLY* (2) GREASE FILTERS (1) 7” ROUND DUCT CONNECTOR (1) 3¼” X 10” DAMPER ASSEMBLY ( FIND INSIDE OF HOOD) (2) NON-DUCTED FILTERS (1) CORD CONNECTION KIT (1) PARTS BAG* CONTAINING: EZ1 COMPONENTS Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
Prepare the Hood NOTE: Since this manual covers many range hood models, some details in the following illustrations may sligthly differ from your unit. 1 ] If present, remove all protective polyfilm from the hood and/or parts. 2 ] Using the finger cup or tab, remove the grease filters from the hood by pushing down and tilting filter out . B C 3 ] BKDF130SSK only: Remove the non-ducted filters and the power cord from inside the hood.
5 ] BKDF130SSK only: Remove 7” Round Duct Plate from top/back of hood (see illustration below). Keep the screws for further use. All other range hood models: Remove 2 screws from top of hood (see illustration below). Keep the screws for further use. BKDF130SSK only 7” ROUND DUCT PLATE 2 SCREWS 2 SCREWS 6 ] Remove Electrical Power Cable Knockout from top (vertical wiring) or back (horizontal wiring) of hood. Install an appropriate strain relief, 1/2” diameter (not included).
DUCTED INSTALLATION ONLY 8 ] Remove 3¼” x 10” vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate as appropriate for your ducting method (see FIGURES 1 A and 1 B).
Prepare the Hood Location NOTE: Before starting installation, read all the steps of these instructions. Use the illustration below to identify your kitchen cabinet type. FRAMED CABINET FRAMELESS CABINET This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets). Please note that the EZ1 one-person installation system is not available for the BKSA2 and NKSA2 Series.
4 ] Drill a 1/8” dia. pilot hole for house wiring, at A location on template. 5 ] Use a sharp pencil or 1/8” drill bit to mark the locations for the appropriate duct access holes (16 locations for 7” round duct, or 4 corner locations for rectangular duct). Remove the template. 6 ] Draw the border for the exhaust ducting by linking its marks (16 for round duct and 4 for rectangular duct), then cut the opening in the cabinet bottom (vertical exhaust) or in the wall (horizontal exhaust).
FRAMELESS CABINET Refer to the marking on brackets to determine the correct installation side and orientation. 3X 7/64” against the wall. Draw a line on the outer edge of the bracket (as shown). keeping the rear end edge leaning on the wall. Use a pencil to mark 3 holes. Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked. Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood screws.
Install the Hood (EZ1 Bracket) NOTE: The following procedure applies to both framed or frameless cabinet installations. 1 ] Run house power cable between service panel and hood location. 2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below); these holes allow the range hood to hang on the brackets (previously installed).
7 ] For framed cabinet, secure the hood to the EZ1 brackets using 4 no. 8-18 x 1/2” metal screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in insets on illustration below). 8 ] For frameless cabinet, secure the hood to the cabinet using 4 no. 8 x 5/8” round head wood screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in insets on illustration below).
Standard Installation (without EZ1 brackets) 1 ] Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.
Install the Hood (Standard Installation) 1 ] Run house power cable between service panel and hood location. Run the house power cable into the hood through the strain relief previously installed in step 6 on page 13. 2 ] Hang hood from (4) mounting screws previously installed. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten screws securely. Attach power cable to the hood using the strain relief.
Connect the Wiring ! WARNING Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. NOTE: For BKDF130SSK range hood, the included cord connection kit can be used to perform the wiring. Refer to instructions packed with the cord connection kit.
Light Bulbs (BKSA2, BKSM1, BKSR1, CKSL1, NKSA2 and NKSH1 Series only) The BKSA2, BKSM1, BKSR1, CKSL1, NKSA2 and NKSH1 Series range hoods require two shielded Halogen Bulbs (120 V, 50 W max., MR16 or PAR16 with GU10 base) (included only with BKSM1, BKSR1, CKSL1 and NKSH1 Series range hoods). ! WARNING Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps.
BKDD1, BKDF1 AND NKDF1 SERIES 1 2 3 4 5 6 COLOR CODE BK BL BN BN/W J6 Override BLACK BLUE BROWN BROWN/WHITE G/Y O R W GREEN/YELLOW ORANGE RED WHITE LED J4 J10 Interface User interface mounted to J10 on back of control board.
BKSA2, BKSR1, NKSA2 AND NKSH1 SERIES COLOR CODE BK BL BN BLACK BLUE BROWN BN/W G/Y O R W Y BROWN/WHITE GREEN/YELLOW ORANGE RED WHITE YELLOW Light Switch 1 Y (Low) 2 BL (High) BK W BK W BK BK Motor Switch 1 2 FAN MOTOR 120 V AC R (Low) BK (High) Line W Neutral Ground G/Y W 6 5 4 3 2 1 BN R O BK G/Y W BN/W INSTALLATION MANUAL WIRING DIAGRAMS 25
BKDD1 SERIES SERVICE PARTS INSTALLATION MANUAL QUANTITY 30" 30" STAINLESS WHITE S97020030 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) 1 1 S97020031 RECIRCULATION COVER PLATE, STAINLESS STEEL (INCLUDING SCREWS) 1 2 S97020534 3¼” X 10” DAMPER ASSEMBLY (INCLUDING SCREWS) 1 1 3 S97020409 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1 1 4 S97020407 FANPELLER (INCLUDING ITEM 5) 1 1 5 SR99420635 CLIP FOR FANPELLER 1 1 6 S99010431-002 GREASE FILTER - MICRO MESH - OBLONG - TYPE C3 (SET
BKDF1 SERIES S97020360 * S97020466† * * * S99527587† S97020470 SR680508† DESCRIPTION RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) RECIRCULATION COVER PLATE, STAINLESS STEEL (INCLUDING SCREWS) 3¼” X 10” DAMPER ASSEMBLY (INCLUDING SCREWS) BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) FANPELLER (INCLUDING ITEM 5) CLIP FOR FANPELLER GREASE FILTER - MICRO MESH - TYPE C2 (SET OF 2) LED MODULE (PAIR) TRANSFORMER 24 V 18 VA (WITH SCREWS) CAPTOUCH CONTROL LED, STAINLESS (WITH SCREWS) CAPTOUCH
NKDF1 SERIES * * * S97020360 * S97020466 * * S99527587 S97020470 2 3 4 5 6 7 8 INSTALLATION MANUAL SERVICE PARTS 9 28 PART NO. S97020030 S97020031 S97020534 S97020409 S97020407 SR99420635 S99010434-002 S97020444 S97020445 S97020431 S97020432 S97020452 S98011637 1 KEY NO.
BKSM1 SERIES KEY NO.
CKSL1 SERIES INSTALLATION MANUAL SERVICE PARTS 30 KEY NO. PART NO.
NKSH1 SERIES KEY NO.
BKSR1 SERIES KEY NO.
BKSA2 AND NKSA2 SERIES PART NO.
WARRANTY INSTALLATION MANUAL 34 Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC and Venmar Ventilation ULC (either being the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase (or such longer period as may be required by applicable law).