3. PREPARE THE HOOD (CONT'D)
3.3 HORIZONTAL DISCHARGE ONLY
1. Remove the large shutoff plate 5 retaining screws located on the BACK of the hood. Discard
the shutoff plate and its screws.
2. Remove the small shutoff plate 10 retaining screws located INSIDE the back of the hood. Set
the screws aside and discard the shutoff plate.
3. Using the 10 screws previously removed in step 2, install the adapter in the inside back of
the hood.
4. Install the damper in the adapter, as shown beside.
4. INSTALL THE HOOD
Run power cable to installation location. Place the hood close to its location and insert
the cable in the hood.
Place the hood under the cabinet and tighten the wire clamp to secure the cable. Make
sure the adapter/damper assembly enters the ducting and the damper opens freely.
Secure the hood by installing and tightening the 4 no. ST4.8 x 15 mm mounting screws
(included) completely at sides locations (A).
HO0049
HO0048
HJ0005
HJ0002
HD0402
A
A