Quick Start Manual

MODELS QTRN050F • QTREN080 • QTREN110
Page 4
SERVICE PARTS
99044373B
INSTALL GRILLE
6. Attach grille
to housing.
Squeeze grille
springs and insert
them into slots on
each side of hous-
ing.
7. Push grille
against
ceiling.
5. Finish ceiling.
Install ceiling material. Cut out around housing.
4. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.
CONNECT WIRING
Order service parts by “Part No. - not by “Key No.
SERVICE NOTE To remove Blower Assembly: Unplug motor.
Remove thumbscrew (11) from motor plate flange. Find the
single TAB on the motor plate (located next to the receptacle).
Push up near motor plate tab while pushing out on side of
housing. Or insert a straight-blade screwdriver into slot in
housing (next to tab) and twist screwdriver.
Replacement parts can
be ordered on our web-
site. Please visit us at
www.nutone.com
Key No. Part No. Description
1 97016466 Housing
2 97016449 Duct Connector-4”
3 98010102 Wiring Plate
4 99170245 Screw, #8-18 X .375
5 97018010 Wire Panel/Harness Assembly
6 97017782 Blower Assembly (QTRN050F)
97017783 Blower Assembly (QTREN080)
97017854 Blower Assembly (QTREN110)
7 97017623 Grille Assembly
(includes key no. 8)
8 99140199 Grille Spring (2 req’d)
9 97018014 Spacer (2 supplied)
10 QTNHB1 Hanger Bar Kit
(QTREN080, QTREN110)
11 99420665 Thumbscrew, #8-18 x .375