Instructions / Assembly

Before Installation
Warnings & Cautions
Ensure that any electrical plugs in the
area are covered or disconnected.
Ensure that the existing plumbing is
up to code.
Identify what material the plumbing/
pipe is composed of.
Turn off water main.
Acquire and install a pressure regulator
with your system.
Maximum working temperature is
113° F (45° C). Minimum working
temperature is 39° F (4°C).
Maximum working pressure is 125 PSI
(8.6 bar) Minimum working pressure
is 7.25 PSI (0.5 bar).
Do not install near electrical appliances.
Do not use with water that is micro-
biologically unsafe or of unknown
quality without adequately treating or
disinfecting water before the system.
The NuvoH2O softener is intended
for the treatment of hard water with
alkaline pH; do not install if inlet water
has a pH of 7.2 or less.
Lubricate (included) O-ring.
Install in a room that protects it from
freezing and excessive heat.
Ensure that the plumbing has been
installed according to the plumbing
code before installation.
Ensure that the water main has been
shut off prior to installation.
Replace cartridge at least every six
months. You may need to replace
cartridges more frequently based on
water usage.
Failure to replace the cartridge in
recommended intervals may result
in poor softener performance and/or
cracks in the housing, causing leakage
and possible flooding.