Datasheet

74AUP1G04 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 7 — 27 June 2012 4 of 22
NXP Semiconductors
74AUP1G04
Low-power inverter
7. Functional description
[1] H = HIGH voltage level; L = LOW voltage level.
8. Limiting values
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For TSSOP5 and SC-74A packages: above 87.5 °C the value of P
tot
derates linearly with 4.0 mW/K.
For XSON6 and X2SON5 packages: above 118 °C the value of P
tot
derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 4. Function table
[1]
Input Output
A Y
LH
HL
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Max Unit
V
CC
supply voltage 0.5 +4.6 V
I
IK
input clamping current V
I
<0V 50 - mA
V
I
input voltage
[1]
0.5 +4.6 V
I
OK
output clamping current V
O
<0V 50 - mA
V
O
output voltage active mode
[1]
0.5 V
CC
+0.5 V
power-down mode
[1]
0.5 +4.6 V
I
O
output current V
O
=0 VtoV
CC
- ±20 mA
I
CC
supply current - +50 mA
I
GND
ground current 50 - mA
T
stg
storage temperature 65 +150 °C
P
tot
total power dissipation T
amb
= 40 °C to +125 °C
[2]
- 250 mW
Table 6. Recommended operating conditions
Symbol Parameter Conditions Min Max Unit
V
CC
supply voltage 0.8 3.6 V
V
I
input voltage 0 3.6 V
V
O
output voltage active mode 0 V
CC
V
power-down mode; V
CC
=0V 0 3.6 V
T
amb
ambient temperature 40 +125 °C
Δt/ΔV input transition rise and fall rate V
CC
= 0.8 V to 3.6 V 0 200 ns/V