Datasheet

74AUP1T58 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 5 — 15 August 2012 7 of 20
NXP Semiconductors
74AUP1T58
Low-power configurable gate with voltage-level translator
V
OH
HIGH-level output voltage V
I
= V
T+
or V
T
I
O
= 20 A; V
CC
= 2.3 V to 3.6 V V
CC
0.1 - - V
I
O
= 2.3 mA; V
CC
= 2.3 V 1.97 - - V
I
O
= 3.1 mA; V
CC
= 2.3 V 1.85 - - V
I
O
= 2.7 mA; V
CC
= 3.0 V 2.67 - - V
I
O
= 4.0 mA; V
CC
= 3.0 V 2.55 - - V
V
OL
LOW-level output voltage V
I
= V
T+
or V
T
I
O
= 20 A; V
CC
= 2.3 V to 3.6 V - - 0.1 V
I
O
= 2.3 mA; V
CC
= 2.3 V - - 0.33 V
I
O
= 3.1 mA; V
CC
= 2.3 V - - 0.45 V
I
O
= 2.7 mA; V
CC
= 3.0 V - - 0.33 V
I
O
= 4.0 mA; V
CC
= 3.0 V - - 0.45 V
I
I
input leakage current V
I
= GND to 3.6 V; V
CC
= 0 V to 3.6 V - - 0.5 A
I
OFF
power-off leakage current V
I
or V
O
= 0 V to 3.6 V; V
CC
= 0 V - - 0.5 A
I
OFF
additional power-off
leakage current
V
I
or V
O
= 0 V to 3.6 V;
V
CC
=0Vto0.2V
--0.5 A
I
CC
supply current V
I
= GND or V
CC
; I
O
= 0 A;
V
CC
= 2.3 V to 3.6 V
--1.5A
I
CC
additional supply current V
CC
= 2.3 V to 2.7 V; I
O
= 0 A
[1]
--4A
V
CC
= 3.0 V to 3.6 V; I
O
= 0 A
[2]
--12A
T
amb
= 40 C to +125 C
V
T+
positive-going threshold
voltage
V
CC
= 2.3 V to 2.7 V 0.60 - 1.10 V
V
CC
= 3.0 V to 3.6 V 0.75 - 1.19 V
V
T
negative-going threshold
voltage
V
CC
= 2.3 V to 2.7 V 0.33 - 0.64 V
V
CC
= 3.0 V to 3.6 V 0.46 - 0.85 V
V
H
hysteresis voltage (V
H
= V
T+
V
T
)
V
CC
= 2.3 V to 2.7 V 0.10 - 0.60 V
V
CC
= 3.0 V to 3.6 V 0.15 - 0.56 V
V
OH
HIGH-level output voltage V
I
= V
T+
or V
T
I
O
= 20 A; V
CC
= 2.3 V to 3.6 V V
CC
0.11 - - V
I
O
= 2.3 mA; V
CC
= 2.3 V 1.77 - - V
I
O
= 3.1 mA; V
CC
= 2.3 V 1.67 - - V
I
O
= 2.7 mA; V
CC
= 3.0 V 2.40 - - V
I
O
= 4.0 mA; V
CC
= 3.0 V 2.30 - - V
V
OL
LOW-level output voltage V
I
= V
T+
or V
T
I
O
= 20 A; V
CC
= 2.3 V to 3.6 V - - 0.11 V
I
O
= 2.3 mA; V
CC
= 2.3 V - - 0.36 V
I
O
= 3.1 mA; V
CC
= 2.3 V - - 0.50 V
I
O
= 2.7 mA; V
CC
= 3.0 V - - 0.36 V
I
O
= 4.0 mA; V
CC
= 3.0 V - - 0.50 V
I
I
input leakage current V
I
= GND to 3.6 V; V
CC
= 0 V to 3.6 V - - 0.75 A
Table 8. Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Typ Max Unit