Datasheet

74AUP2G0604 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 1 — 23 November 2012 9 of 20
NXP Semiconductors
74AUP2G0604
Low-power inverting buffer with open-drain and inverter
[1] All typical values are measured at nominal V
CC
.
[2] t
pd
is the same as t
PLH
and t
PHL
(2A to 2Y) and t
PLZ
and t
PZL
(1A to 1Y).
[3] All specified values are the average typical values over all stated loads.
[4] C
PD
is used to determine the dynamic power dissipation (P
D
in W).
P
D
=C
PD
V
CC
2
f
i
N where:
f
i
= input frequency in MHz;
C
L
= load capacitance in pF;
N = number of inputs switching;
[5] C
PD
is used to determine the dynamic power dissipation (P
D
in W).
P
D
=C
PD
V
CC
2
f
i
N+(C
L
V
CC
2
f
o
) where:
f
i
= input frequency in MHz;
f
o
= output frequency in MHz;
C
L
= load capacitance in pF;
V
CC
= supply voltage in V;
N = number of inputs switching;
(C
L
V
CC
2
f
o
) = sum of the outputs.
C
L
= 5 pF, 10 pF, 15 pF and 30 pF
C
PD
power
dissipation
capacitance
1A to 1Y; f
i
=1 MHz; V
I
= GND to V
CC
[3]
[4]
V
CC
= 0.8 V - 0.5 - - - - pF
V
CC
= 1.1 V to 1.3 V - 0.6 - - - - pF
V
CC
= 1.4 V to 1.6 V - 0.7 - - - - pF
V
CC
= 1.65 V to 1.95 V - 0.7 - - - - pF
V
CC
= 2.3 V to 2.7 V - 1.0 - - - - pF
V
CC
= 3.0 V to 3.6 V - 1.2 - - - - pF
2A to 2Y; f
i
=1 MHz; V
I
= GND to V
CC
[3]
[5]
V
CC
= 0.8 V - 2.5 - - - - pF
V
CC
= 1.1 V to 1.3 V - 2.7 - - - - pF
V
CC
= 1.4 V to 1.6 V - 2.8 - - - - pF
V
CC
= 1.65 V to 1.95 V - 3.0 - - - - pF
V
CC
= 2.3 V to 2.7 V - 3.5 - - - - pF
V
CC
= 3.0 V to 3.6 V - 4.0 - - - - pF
Table 9. Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 8.
Symbol Parameter Conditions 25 C 40 C to +125 C Unit
Min Typ
[1]
Max Min Max
(85 C)
Max
(125 C)