Datasheet

74AUP2G126 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
Product data sheet Rev. 9 — 11 February 2013 7 of 24
NXP Semiconductors
74AUP2G126
Low-power dual buffer/line driver; 3-state
I
OFF
additional power-off
leakage current
V
I
or V
O
= 0 V to 3.6 V;
V
CC
= 0 V to 0.2 V
--0.6 A
I
CC
supply current V
I
= GND or V
CC
; I
O
=0A;
V
CC
= 0.8 V to 3.6 V
--0.9A
I
CC
additional supply current data input; V
I
= V
CC
0.6 V; I
O
=0A;
V
CC
=3.3V
[1]
--50A
nOE input; V
I
= V
CC
0.6 V; I
O
= 0 A;
V
CC
=3.3V
[1]
- - 120 A
all inputs; V
I
= GND to 3.6 V;
nOE = GND; V
CC
= 0.8 V to 3.6 V
[2]
--1A
T
amb
= 40 C to +125 C
V
IH
HIGH-level input voltage V
CC
= 0.8 V 0.75 V
CC
-- V
V
CC
= 0.9 V to 1.95 V 0.70 V
CC
-- V
V
CC
= 2.3 V to 2.7 V 1.6 - - V
V
CC
= 3.0 V to 3.6 V 2.0 - - V
V
IL
LOW-level input voltage V
CC
= 0.8 V - - 0.25 V
CC
V
V
CC
= 0.9 V to 1.95 V - - 0.30 V
CC
V
V
CC
= 2.3 V to 2.7 V - - 0.7 V
V
CC
= 3.0 V to 3.6 V - - 0.9 V
V
OH
HIGH-level output voltage V
I
= V
IH
or V
IL
I
O
= 20 A; V
CC
= 0.8 V to 3.6 V V
CC
0.11 - - V
I
O
= 1.1 mA; V
CC
= 1.1 V 0.6 V
CC
-- V
I
O
= 1.7 mA; V
CC
= 1.4 V 0.93 - - V
I
O
= 1.9 mA; V
CC
= 1.65 V 1.17 - - V
I
O
= 2.3 mA; V
CC
= 2.3 V 1.77 - - V
I
O
= 3.1 mA; V
CC
= 2.3 V 1.67 - - V
I
O
= 2.7 mA; V
CC
= 3.0 V 2.40 - - V
I
O
= 4.0 mA; V
CC
= 3.0 V 2.30 - - V
V
OL
LOW-level output voltage V
I
= V
IH
or V
IL
I
O
= 20 A; V
CC
= 0.8 V to 3.6 V - - 0.11 V
I
O
= 1.1 mA; V
CC
= 1.1 V - - 0.33 V
CC
V
I
O
= 1.7 mA; V
CC
= 1.4 V - - 0.41 V
I
O
= 1.9 mA; V
CC
= 1.65 V - - 0.39 V
I
O
= 2.3 mA; V
CC
= 2.3 V - - 0.36 V
I
O
= 3.1 mA; V
CC
= 2.3 V - - 0.50 V
I
O
= 2.7 mA; V
CC
= 3.0 V - - 0.36 V
I
O
= 4.0 mA; V
CC
= 3.0 V - - 0.50 V
I
I
input leakage current V
I
= GND to 3.6 V; V
CC
= 0 V to 3.6 V - - 0.75 A
I
OZ
OFF-state output current V
I
= V
IH
or V
IL
; V
O
= 0 V to 3.6 V;
V
CC
= 0 V to 3.6 V
--0.75 A
I
OFF
power-off leakage current V
I
or V
O
= 0 V to 3.6 V; V
CC
= 0 V - - 0.75 A
Table 7. Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Typ Max Unit