Datasheet

September 1993 6
Philips Semiconductors Product specification
Dual 2-to-4 line decoder/demultiplexer 74HC/HCT139
DC CHARACTERISTICS FOR HCT
For the DC characteristics see
“74HC/HCT/HCU/HCMOS Logic Family Specifications”
.
Output capability: standard
I
CC
category: MSI
Note to HCT types
The value of additional quiescent supply current (I
CC
) for a unit load of 1 is given in the family specifications.
To determine I
CC
per input, multiply this value by the unit load coefficient shown in the table below.
AC CHARACTERISTICS FOR 74HCT
GND = 0 V; t
f
= t
f
= 6 ns; C
L
= 50 pF
INPUT UNIT LOAD COEFFICIENT
1A
n
2A
n
nE
0.70
0.70
1.35
SYMBOL PARAMETER
T
amb
(°C)
UNIT
TEST CONDITIONS
74HCT
V
CC
(V)
WAVEFORMS
+25 40 to +85 40 to +125
min. typ. max. min. max. min. max.
t
PHL
/ t
PLH
propagation delay
nA
n
to Y
n
16 34 43 51 ns 4.5 Fig.6
t
PHL
/ t
PLH
propagation delay
nE to nY
n
16 34 43 51 ns 4.5 Fig.7
t
THL
/ t
TLH
output transition
time