7. Limiting values
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For DIP16 packages: above 70 C the value of P
tot
derates linearly at 12 mW/K.
For SO16 packages: above 70 C the value of P
tot
derates linearly at 8 mW/K.
For SSOP16 and TSSOP16 packages: above 60 C the value of P
tot
derates linearly at 5.5 mW/K.
8. Recommended operating conditions
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Max Unit
V
CC
supply voltage 0.5 +7.0 V
I
IK
input clamping current V
I
< 0.5 V or V
I
>V
CC
+ 0.5 V
[1]
- 20 mA
I
OK
output clamping current V
O
< 0.5 V or V
O
> V
CC
+ 0.5 V
[1]
- 20 mA
I
O
output current V
O
= 0.5 V to V
CC
+ 0.5 V - 25 mA
I
CC
supply current - 50 mA
I
GND
ground current - 50 mA
T
stg
storage temperature 65 +150 C
P
tot
total power dissipation DIP16 package
[2]
-750mW
SO16 package
[2]
-500mW
SSOP16 package
[2]
-500mW
TSSOP16 package
[2]
-500mW
Table 5. Recommended operating conditions
Symbol Parameter Conditions Min Typ Max Unit
74HC193
V
CC
supply voltage 2.0 5.0 6.0 V
V
I
input voltage 0- V
CC
V
V
O
output voltage 0 - V
CC
V
T
amb
ambient temperature 40 +25 +125 C
t/V input transition rise and
fall rate
V
CC
= 2.0 V - - 625 ns/V
V
CC
= 4.5 V - 1.67 139 ns/V
V
CC
= 6.0 V --83ns/V
74HCT193
V
CC
supply voltage 4.5 5.0 5.5 V
V
I
input voltage 0- V
CC
V
V
O
output voltage 0 - V
CC
V
T
amb
ambient temperature 40 +25 +125 C
t/V input transition rise and
fall rate
V
CC
= 4.5 V - 1.67 139 ns/V