Datasheet

9397 750 14501 © Koninklijke Philips Electronics N.V. 2005. All rights reserved.
Product data sheet Rev. 03 — 4 February 2005 12 of 21
Philips Semiconductors
74LV164
8-bit serial-in/parallel-out shift register
Measurement points are given in Table 9.
V
OL
and V
OH
are typical output voltage drop that occur with the output load.
The shaded areas indicate when the input is permitted to change for predictable output
performance.
Fig 8. Data set-up and hold times inputs (Dn) to clock (CP)
Table 9: Measurement points
Supply voltage Input Output
V
CC
V
M
V
M
1.2 V 0.5 × V
CC
0.5 × V
CC
2.0 V 0.5 × V
CC
0.5 × V
CC
2.7 V 1.5 V 1.5 V
3.0 V to 3.6 V 1.5 V 1.5 V
4.5 V to 5.5 V 0.5 × V
CC
0.5 × V
CC
001aac428
GND
GND
t
h
t
su
t
h
t
su
V
M
V
M
V
M
V
I
V
OH
V
OL
V
I
Qn output
CP input
Dn input