Datasheet

KTY82_SER_4 © NXP B.V. 2008. All rights reserved.
Product data sheet Rev. 04 — 14 January 2008 3 of 17
NXP Semiconductors
KTY82 series
Silicon temperature sensors
4. Marking
5. Limiting values
Table 4. Marking codes
Type number Marking code
KTY82/110 110
KTY82/120 120
KTY82/121 121
KTY82/122 122
KTY82/150 150
KTY82/151 151
KTY82/210 210
KTY82/220 220
KTY82/221 221
KTY82/222 222
KTY82/250 250
KTY82/251 251
KTY82/252 252
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter Conditions Min Max Unit
I
sen(cont)
continuous sensor current in free air; T
amb
=25°C - 10 mA
in free air; T
amb
= 150 °C-2mA
T
amb
ambient temperature 55 +150 °C