Datasheet

LPC111X All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2014. All rights reserved.
Product data sheet Rev. 9.2 — 26 March 2014 93 of 127
NXP Semiconductors
LPC1110/11/12/13/14/15
32-bit ARM Cortex-M0 microcontroller
11.6 I
2
C-bus
[1] See the I
2
C-bus specification UM10204 for details.
[2] Parameters are valid over operating temperature range unless otherwise specified.
[3] t
HD;DAT
is the data hold time that is measured from the falling edge of SCL; applies to data in transmission
and the acknowledge.
[4] A device must internally provide a hold time of at least 300 ns for the SDA signal (with respect to the
V
IH
(min) of the SCL signal) to bridge the undefined region of the falling edge of SCL.
[5] C
b
= total capacitance of one bus line in pF.
[6] The maximum t
f
for the SDA and SCL bus lines is specified at 300 ns. The maximum fall time for the SDA
output stage t
f
is specified at 250 ns. This allows series protection resistors to be connected in between the
SDA and the SCL pins and the SDA/SCL bus lines without exceeding the maximum specified t
f
.
[7] In Fast-mode Plus, fall time is specified the same for both output stage and bus timing. If series resistors
are used, designers should allow for this when considering bus timing.
[8] The maximum t
HD;DAT
could be 3.45 s and 0.9 s for Standard-mode and Fast-mode but must be less than
the maximum of t
VD;DAT
or t
VD;ACK
by a transition time (see UM10204). This maximum must only be met if
the device does not stretch the LOW period (t
LOW
) of the SCL signal. If the clock stretches the SCL, the
data must be valid by the set-up time before it releases the clock.
[9] t
SU;DAT
is the data set-up time that is measured with respect to the rising edge of SCL; applies to data in
transmission and the acknowledge.
[10] A Fast-mode I
2
C-bus device can be used in a Standard-mode I
2
C-bus system but the requirement
t
SU;DAT
= 250 ns must then be met. This will automatically be the case if the device does not stretch the
LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must
output the next data bit to the SDA line t
r(max)
+ t
SU;DAT
= 1000 + 250 = 1250 ns (according to the
Standard-mode I
2
C-bus specification) before the SCL line is released. Also the acknowledge timing must
meet this set-up time.
Table 28. Dynamic characteristic: I
2
C-bus pins
[1]
T
amb
=
40
C to +105
C.
[2]
Symbol Parameter Conditions Min Max Unit
f
SCL
SCL clock
frequency
Standard-mode 0 100 kHz
Fast-mode 0 400 kHz
Fast-mode Plus 0 1 MHz
t
f
fall time
[4][5][6][7]
of both SDA and
SCL signals
Standard-mode
- 300 ns
Fast-mode 20 + 0.1 C
b
300 ns
Fast-mode Plus - 120 ns
t
LOW
LOW period of
the SCL clock
Standard-mode 4.7 - s
Fast-mode 1.3 - s
Fast-mode Plus 0.5 - s
t
HIGH
HIGH period of
the SCL clock
Standard-mode 4.0 - s
Fast-mode 0.6 - s
Fast-mode Plus 0.26 - s
t
HD;DAT
data hold time
[3][4][8]
Standard-mode 0 - s
Fast-mode 0 - s
Fast-mode Plus 0 - s
t
SU;DAT
data set-up
time
[9][10]
Standard-mode 250 - ns
Fast-mode 100 - ns
Fast-mode Plus 50 - ns