Datasheet

Analog Integrated Circuit Device Data
Freescale Semiconductor 100
34709
Functional Block Description
Table 91. Register 8, Regulator Fault Sense
Name Bit # R/W Reset Default Description
SW1FAULT 0 R NONE S
SW1 fault detection
Reserved 1 R - -
Reserved
SW2FAULT 2 R NONE S
SW2 fault detection
SW3FAULT 3 R NONE S
SW3 fault detection
SW4AFAULT 4 R NONE S
SW4A fault detection
SW4BFAULT 5 R NONE S
SW4B fault detection
SW5FAULT 6 R NONE S
SW5 fault detection
SWBSTFAULT 7 R NONE S
SWBST fault detection
VUSBFAULT 8 R NONE S
VUSB fault detection
VUSB2FAULT 9 R NONE S
VUSB2 fault detection
VDACFAULT 10 R NONE S
VDAC fault detection
VGEN1FAULT 11 R NONE S
VGEN1 fault detection
VGEN2FAULT 12 R NONE S
VGEN2 fault detection
Unused 13-22 R 0
Not available
REGSCPEN 23 R/W RESETB 0
Register short-circuit protect enable. This bit should be set to 1 to
reduce power dissipation on the external pass LDOs (VUSB2, VGEN2,
and VDAC). When a short-circuit condition is detected, the LDO’s
VxEN bit is set to 0, disabling the LDO and an SCPI interrupt will be
generated
Back to SPI/I2C Register Map
Table 92. Register 9, Reserved
Name Bit # R/W Reset Default Description
Reserved 23-0 R - -
Reserved
Table 93. Register 10 to 12, Unused
Name Bit # R/W Reset Default Description
Reserved 23-0 R - -
Reserved
Table 94. Register 13, Power Control 0
Name Bit # R/W Reset Default Description
PCEN 0 R/W RTCPORB 0
Power cut enable
PCCOUNTEN 1 R/W RTCPORB 0
Power cut counter enable
WARMEN 2 R/W RTCPORB 0
Warm start enable
USEROFFSPI 3 R/W RESETB 0
SPI command for entering user off modes
DRM 4 R/W RTCPORB
(67)
0
Keeps VSRTC and CLK32KMCU on for all states
USEROFFCLK 5 R/W RTCPORB 0
Keeps the CLK32KMCU active during user off
CLK32KMCUEN 6 R/W RTCPORB 1
Enables the CLK32KMCU