Register Descriptions
56F8014 Technical Data, Rev. 11
Freescale Semiconductor 55
5.5.5.2 PWM Fault Interrupt Priority Level (PWM_F IPL)—
Bits 7–6
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2
5.5.5.3 Reload PWM Interrupt Priority Level (PWM_RL IPL)—
Bits 5–4
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2
5.5.5.4 ADC Zero Crossing or Limit Error Interrupt Priority Level
(ADC_ZC_LE IPL)— Bits 3–2
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2
5.5.5.5 ADCB Conversion Complete Interrupt Priority Level
(ADCB_CC IPL)—Bits 1–0
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2