Datasheet

Development Support
MC68HC908GP32 Data Sheet, Rev. 10
226 Freescale Semiconductor
event, the CGMOUT frequency is equal to the CGMXCLK frequency, and the OSC1 input directly
generates internal bus clocks. In this case, the OSC1 signal must have a 50% duty cycle at maximum bus
frequency.
If monitor mode was entered with V
TST
on IRQ, then the COP is disabled as long as V
TST
is applied to
either
IRQ or RST.
This condition states that as long as V
TST
is maintained on the IRQ pin after entering monitor mode, or if
V
TST
is applied to RST after the initial reset to get into monitor mode (when V
TST
was applied to IRQ),
then the COP will be disabled. In the latter situation, after V
TST
is applied to the RST pin, V
TST
can be
removed from the
IRQ pin in the interest of freeing the IRQ for normal functionality in monitor mode.
18.3.1.2 Forced Monitor Mode
If entering monitor mode without high voltage on
IRQ (where applied voltage is either V
DD
or V
SS
), then
all port C pin requirements and conditions, including the PTC3 frequency divisor selection, are not in
effect. This is to reduce circuit requirements when performing in-circuit programming.
If
IRQ = V
DD
on monitor mode entry, an external oscillator of 9.8304 MHz is required for a 9600 baud rate.
If
IRQ = V
SS
on monitor mode entry, the monitor firmware initializes a 9600 baud rate using a 32.768 kHz
crystal.
When forced monitor mode is entered, the COP is always disabled regardless of the state of
IRQ or RST.
NOTE
If the reset vector is blank and monitor mode is entered, the chip will see an
additional reset cycle after the initial POR reset. Once the part has been
programmed, the traditional method of applying a voltage, V
TST
, to IRQ
must be used to enter monitor mode.
18.3.1.3 Monitor Vectors
In monitor mode, the MCU uses different vectors for reset, SWI (software interrupt), and break interrupt
than those for user mode. The alternate vectors are in the $FE page instead of the $FF page and allow
code execution from the internal monitor firmware instead of user code.
NOTE
Exiting monitor mode after it has been initiated by having a blank reset
vector requires a power-on reset (POR). Pulling
RST low will not exit
monitor mode in this situation.
Table 18-2 summarizes the differences between user mode and monitor mode.
Table 18-2. Mode Differences
Modes
Functions
Reset
Vector High
Reset
Vector Low
Break
Vector High
Break
Vector Low
SWI
Vector High
SWI
Vector Low
User $FFFE $FFFF $FFFC $FFFD $FFFC $FFFD
Monitor $FEFE $FEFF $FEFC $FEFD $FEFC $FEFD